寶帝在線式流量變送器,直銷BURKERT流量變送器
The 8034 flow rate indicator can easily be installed into any Bürkert INLINE fitting system S030.
Minimum straight upstream and downstream distances must be observed. According to the pipe’s design, necessary distances can be bigger or use a
flow conditioner to obtain the best accuracy. For more information, please refer to EN ISO 5167-1.
EN ISO 5167-1 prescribes the straight inlet and outlet distances that must be complied with when installing fittings in pipe lines in order to achieve
calm flow conditions. The most important layouts that could lead to turbulence in the flow are shown below, together with the associated prescribed
minimum inlet and outlet distances. These ensure calm, problem-free measurement conditions at the measurement point.
zui大誤差以測量范圍的%表示:
標準K系數(shù)校正:≤×±(0.5% o.F.S. +2.5%
在線校正(Teach-in):≤±0.5% o.F.S.
Complete device data (fitting + electronic module)
Pipe diameter DN 06 to 65
Measuring range 0.5 to 10 m/s
Medium temperature with
Fluid pressure max. PN10 (with plastic fitting) - PN16 (with metal fitting)
Viscosity 300 cSt. max. (solid particles rate: 1%)
Accuracy ≤ ±10% of Reading1) (0.8 ... 2 m/s)
≤ ±4% of Reading1) (2 ... 10 m/s)
Repeatability ≤ ±1% of Reading1)
Power supply (V+) 2 batteries 1.5 VDC (Type LR14)
Display White background, red pointer and black scale
聯(lián)系方式
郵箱:15214375780@163.com 地址:上海市松江區(qū)高技路655號4棟413-415